The terms you will meet on transformer datasheets and in the guides, explained in plain language.
- VA (volt-ampere)
- The power rating of a transformer: rated voltage × rated current. For a transformer with several secondaries, the VA is the sum of all of them.
- Primary
- The winding connected to the supply, usually 230 V AC mains in India.
- Secondary
- The output winding(s). A transformer can have several, each with its own voltage and current rating.
- Centre tap
- A connection at the midpoint of a secondary, written as 24-0-24 or 30-0-30. It is used to make split (±) supplies for amplifiers.
- Turns ratio
- Primary turns divided by secondary turns. The voltage ratio follows the turns ratio.
- Regulation
- How much the output voltage drops from no load to full load, as a percentage. Smaller transformers have higher (worse) regulation.
- Inrush current
- The large current surge that can flow for a few cycles when a transformer is switched on, caused by core saturation. More.
- Remanence
- The magnetism a core keeps after the supply is removed. High remanence contributes to inrush current.
- Saturation
- The point at which the core cannot carry more magnetic flux. Beyond it, the primary current rises very sharply.
- Flux density
- Magnetic flux per unit area of core, measured in tesla (T). The designer chooses it as a balance between size, losses and inrush.
- CRGO steel
- Cold-rolled grain-oriented silicon steel. It carries flux best along its grain, which suits the continuous strip of a toroidal core.
- Stray (leakage) field
- Magnetic field that escapes the core into the surroundings, where it can induce hum in nearby circuits. It is very low in toroids.
- Electrostatic shield
- A thin foil layer between primary and secondary, connected to earth, that reduces capacitive coupling of mains noise.
- Shorted turn
- Any closed conductive loop through the centre of a toroid, for example a mounting bolt touching the chassis at both ends. It causes heavy current and heating. More.
- Soft-start
- A circuit that limits inrush current at switch-on, typically an NTC thermistor or a resistor bypassed by a relay.
- Slow-blow (T) fuse
- A time-delay fuse that tolerates a short surge but still opens on a sustained overload. It is required on toroid primaries.
- Insulation class
- The maximum temperature the insulation system is rated for, e.g. Class B (130 °C) or Class F (155 °C).
- Hi-pot test
- A high-voltage test between windings, and between windings and core, to verify insulation strength.
- Potted centre
- A toroid whose centre hole is filled with resin so it can be mounted with a single screw, useful for vertical or high-vibration mounting.
- DC offset (on mains)
- A small DC component on the AC supply, caused by half-wave loads. It can make toroidal transformers buzz audibly.